Energy
Efficiency Comparison |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
by Bryan A. Thompson |
|
Last Updated 2/12/03 |
|
|
Constants |
|
Gasoline Cost |
$1.59 |
per gallon |
|
Propane Cost |
$1.49 |
per gallon in bulk |
|
Wood Cost |
$75.00 |
per cord of hickory |
|
Propane Storage Cost |
$4.26 |
per gallon in 20lb bulk cylinders |
|
Liquid Fuel Storage Cost |
$1.20 |
per gallon in 5 gallon cans |
|
|
Device |
Rate of Fuel
Consumption |
Rate of
Consumption Units |
Operating Fuel
Costs ($/hr) |
Operating Costs
from Stored Fuel ($/hr) |
Energy Input
(KWH) |
Energy Input
(BTU) |
Energy Output
(KWH) |
Energy Output
(BTU) |
Energy Efficiency
(%) |
Energy Cost
($/KWH Output) |
Energy Cost from
Stored Fuel ($/KWH Output) |
Cost to Purchase
Device ($) |
Energy
Distribution Cost ($) |
Maintenance Costs
($/hr) |
Total Cost of
Operation ($/hr) |
Notes |
|
Generator +
Gasoline |
0.27500 |
Gallons/Hour |
$0.437 |
$0.767 |
10.0815 |
34407.84983 |
1.6 |
5460.750853 |
15.87065417 |
$0.0434 |
$0.4795 |
$1,000.00 |
$925.000 |
Unknown |
|
Honda EU2000i with
Eco-Throttle + Emergency Power Distribution System |
|
Generator +
Propane |
0.30250 |
Gallons/Hour |
$0.451 |
$1.738 |
8.11305 |
27689.59044 |
1.6 |
5460.750853 |
19.72131319 |
$0.0555 |
$1.0860 |
$1,000.00 |
$925.000 |
Unknown |
|
Honda EU2000i with
Eco-Throttle + Emergency Power Distribution System |
|
DayGlo
Propane Heater on Low |
0.04595 |
Gallons/Hour |
$0.068 |
$0.264 |
1.231186 |
4202 |
1.172 |
4000 |
95.19276535 |
$0.0556 |
$0.2252 |
$100.00 |
$50.000 |
Unknown |
|
A bulk adapter and
two hoses are included in distribution. |
|
|
|
|
Wood stove |
0.00167 |
Cords/Hour |
$0.125 |
$0.125 |
14.65 |
50000 |
11.72 |
40000 |
80 |
$0.0085 |
$0.0107 |
$1,200.00 |
$0.000 |
Unknown |
|
Hickory wood with
moisture content less than 20% |
|
Coleman
Propane Stove |
0.20792 |
Gallons/Hour |
$0.310 |
$1.194 |
5.576376 |
19032 |
4.688 |
16000 |
84.06893653 |
$0.0555 |
$0.2548 |
$40.00 |
$50.000 |
Unknown |
|
A bulk adapter and
two hoses are included in distribution. |
|
Coleman
Gasoline Stove |
0.15625 |
Gallons/Hour |
$0.248 |
$0.436 |
5.6765625 |
19373.93345 |
6.153 |
21000 |
108.3930636 |
$0.0438 |
$0.0708 |
$50.00 |
$0.000 |
Unknown |
|
Manufacturers specs
are probably overly optimistic |
|
Solar Panel
(1 square meter) |
0.00000 |
Watts/Hour |
$0.000 |
$0.000 |
1 |
3412.969283 |
0.10929 |
373.003413 |
0.10929 |
$0.0000 |
$0.0000 |
$552.00 |
$925.000 |
Unknown |
|
Panels and Emergency
Power Distribution System |
|
Wind Turbine |
Unknown |
Watts/Hour |
$0.000 |
$0.000 |
Unknown |
Unknown |
Unknown |
Unknown |
Unknown |
$0.0000 |
$0.0000 |
Unknown |
$925.000 |
Unknown |
|
Turbines and
Emergency Power Distribution System |
|
Micro
Hydroelectric Turbine |
Unknown |
Watts/Hour |
$0.000 |
$0.000 |
Unknown |
Unknown |
Unknown |
Unknown |
30 |
$0.0000 |
$0.0000 |
Unknown |
$925.000 |
Unknown |
|
Turbines and
Emergency Power Distribution System |
|
|
Notes |
|
Bold fields indicate information provided by manufacturer
specifications, other fields are calculated |
|
Energy
Distribution costs are system (not per-device) costs for required materials
for conversion to a usable form (an inverter), and distribution supplies such
as extension cords, power strips, propane hoses and adapters, etc. These costs do not include energy storage
costs. |
|
Operating
costs from stored fuel have been included to help plan for energencies |
|
|
Conversion Factors |
|
|
Volume |
|
1 gal = 0.00378541m^3 |
|
1 ft^3 = 0.02831685 m^3 |
|
1 m^3 =
35.3146 ft^3 |
|
1 gal =
0.133680 ft^3 |
|
|
Energy |
|
1 cal = 4.186 J |
|
1eV = 1.6E-19
J |
|
1KWH = 3.6E6
J |
|
1 BTU =
1.054E3 J |
|
1 J = 1 W*sec |
|
|
Power |
|
1W = 1J/sec |
|
1BTU = 3.412
Watt Hours |
|
1 BTU/hr =
0.293W |
|
1 BTU = .293
W*hr |
|
1 BTU = Amount of heat needed to increase the temperature of 1
pint (=1lb) of water 1 degree Farenheit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|